OI 0131941A
Dual Fuel LevelDual Fuel Level
Dual Fuel LevelDual Fuel Level
Dual Fuel Level
(FL-2RA-12, FL-2RA-24 and FL-2CA)(FL-2RA-12, FL-2RA-24 and FL-2CA)
(FL-2RA-12, FL-2RA-24 and FL-2CA)(FL-2RA-12, FL-2RA-24 and FL-2CA)
(FL-2RA-12, FL-2RA-24 and FL-2CA)
(2nd Generation Instruments)(2nd Generation Instruments)
(2nd Generation Instruments)(2nd Generation Instruments)
(2nd Generation Instruments)
Operating and Installation InstructionsOperating and Installation Instructions
Operating and Installation InstructionsOperating and Installation Instructions
Operating and Installation Instructions
Electronics International Inc. Electronics International Inc.
Electronics International Inc. Electronics International Inc.
Electronics International Inc.
®®
®®
®
10/15/01
63296 Powell Butte Hwy • Bend, OR 97701 • (541) 318-6060 • Buy-EI.com63296 Powell Butte Hwy • Bend, OR 97701 • (541) 318-6060 • Buy-EI.com
63296 Powell Butte Hwy • Bend, OR 97701 • (541) 318-6060 • Buy-EI.com63296 Powell Butte Hwy • Bend, OR 97701 • (541) 318-6060 • Buy-EI.com
63296 Powell Butte Hwy • Bend, OR 97701 • (541) 318-6060 • Buy-EI.com
Model:Model:
Model:Model:
Model:
S/N:S/N:
S/N:S/N:
S/N:
You must read this manual before installing or operating the instrument. This
manual contains warranty and other information that may affect your decision
to install this product and/or the safety of your aircraft.
Przeglądanie stron 0
1 2 3 4 5 6 ... 25 26

Podsumowanie treści

Strona 1 - Dual Fuel Level

OI 0131941ADual Fuel LevelDual Fuel LevelDual Fuel LevelDual Fuel LevelDual Fuel Level(FL-2RA-12, FL-2RA-24 and FL-2CA)(FL-2RA-12, FL-2RA-24 and FL-2

Strona 2 - ***** Must Read *****

Route the External WRoute the External WRoute the External WRoute the External WRoute the External Warning Control Line:arning Control Line:arning Con

Strona 3 - ContentsContents

Selecting the Proper Filter:Selecting the Proper Filter:Selecting the Proper Filter:Selecting the Proper Filter:Selecting the Proper Filter:The filter

Strona 4 - Warranty

Programming the FilterProgramming the FilterProgramming the FilterProgramming the FilterProgramming the Filter, Operating Mode and Resolution:, Operat

Strona 5

11Calibration Issues:Calibration Issues:Calibration Issues:Calibration Issues:Calibration Issues:The FL-2 must be calibrated to the left and right fue

Strona 6 - ***** MUST READ *****

12Calibrate the Left FCalibrate the Left FCalibrate the Left FCalibrate the Left FCalibrate the Left Fuel Tuel Tuel Tuel Tuel Tank:ank:ank:ank:ank:1.

Strona 7

13 Note: If you want to manually program the Sensor Counts, push and hold the Enter Button at the back ofthe FL-2 (with the Sensor Counts displ

Strona 8

1413. Place the Selector Switch into the right position. The FL-2 will display the last programmed SensorCounts for this cal point. Tap the Ent

Strona 9

15Calibrating the Right FCalibrating the Right FCalibrating the Right FCalibrating the Right FCalibrating the Right Fuel Tuel Tuel Tuel Tuel Tank:ank:

Strona 10

FLFLFLFLFL-2RA-12 and FL-2RA-12 and FL-2RA-12 and FL-2RA-12 and FL-2RA-12 and FL-2RA-24-2RA-24-2RA-24-2RA-24-2RA-24 Wiring Diagram Wiring Diagram Wiri

Strona 11

FL-2RA-12 and FL-2RA-24FL-2RA-12 and FL-2RA-24FL-2RA-12 and FL-2RA-24FL-2RA-12 and FL-2RA-24FL-2RA-12 and FL-2RA-24Circular ConnectorCircular Connecto

Strona 12

FL-2FL-2FL-2FL-2FL-2Important NoticeImportant NoticeImportant NoticeImportant NoticeImportant Notice***** Must Read ********** Must Read ********** Mu

Strona 13 - Calibration Issues:

FLFLFLFLFL-2CA-2CA-2CA-2CA-2CA Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram Wiring DiagramCircular Connector3' Analog LED Lighting

Strona 14

19FL-2CAFL-2CAFL-2CAFL-2CAFL-2CACircular ConnectorCircular ConnectorCircular ConnectorCircular ConnectorCircular ConnectorConnecting Cable Harness, Ba

Strona 15

20Specifications and Operating FeaturesSpecifications and Operating FeaturesSpecifications and Operating FeaturesSpecifications and Operating Features

Strona 16 - 10561056

FLFLFLFLFL-2 F-2 F-2 F-2 F-2 Fuel Level Instrumentuel Level Instrumentuel Level Instrumentuel Level Instrumentuel Level InstrumentandandandandandFFFFF

Strona 17

4. As you lower the sensor float slightlyslightlyslightlyslightlyslightly from the top of the tank, the resistance should start toincrease. If it do

Strona 18 - Airframe Ground

TTTTTechnical Notesechnical Notesechnical Notesechnical Notesechnical NotesPage ThreeAs a general rule, resistive sensors can be unreliable. We teste

Strona 19 - Note: See Wiring Diagram for

Capacitive and Resistive FCapacitive and Resistive FCapacitive and Resistive FCapacitive and Resistive FCapacitive and Resistive Fuel Level Sensor Iss

Strona 20 - Wire Harness

ContentsContentsContentsContentsContentsWWWWWarranty ...arranty ...

Strona 21

Warranty1209921Electronics International Inc. warrants this instrument and system components to be free from defects in materialsand workmanship for a

Strona 22

3Operating InstructionsOperating InstructionsOperating InstructionsOperating InstructionsOperating InstructionsFL-2RA & FL-2CAFL-2RA & FL-

Strona 23

Note:Note:Note:Note:Note: To acknowledge a blinking LED (i.e., to stop the blinking), change the position of the Tank SelectorSwitch. Once a blinkin

Strona 24 - Page Two

than the actual fuel in the tanks when the tanks are full. When the fuel level drops to a point where thefuel sensors start to detect a change, the d

Strona 25

63. Preflight - Do not rely on the FL-2 to determine the fuel level in the fuel tanks. The pilot must3. Preflight - Do not rely on the FL-2 to de

Strona 26

77. The FL-2 must be calibrated to the aircraft fuel system and its accuracy must be verified before flyingThe FL-2 must be calibrated to the aircraf